Is my boiler's condensate pipe frozen?

Short answer

If it's below freezing outside and the boiler has stopped, is gurgling or is showing a fault code, it may well be. Check the plastic waste pipe that runs from the boiler to an outside drain. Warm water poured slowly along it often gets the boiler going again.

Modern boilers make a small amount of waste water as they run. It drains away through a plastic pipe, called the condensate pipe. Where that pipe runs outside, the water in it can freeze in a hard frost, and the boiler shuts itself down rather than fill up with water.

How to tell

  • It’s below freezing outside, or has been overnight
  • The boiler was fine yesterday and now won’t fire, or fires and cuts out
  • There’s a gurgling or bubbling noise from the boiler or the pipe
  • A fault code has come up on the display. Your manual will say which code means a blocked condensate

Finding the pipe

It’s plastic, usually white or grey, and it comes out through the wall near the boiler and runs down to a drain. It’s usually the only plastic pipe coming through the wall from the boiler. If there’s a copper one nearby, that’s the pressure relief pipe. Leave it alone.

The ice is usually at the open end, by the drain, or at a bend.

Thawing it

  1. Warm some water. Hot from the tap is plenty. Not boiling: boiling water can crack the pipe and scald you.
  2. Pour it slowly along the pipe, starting at the frozen end and working back. A watering can makes it easier.
  3. A hot water bottle or a microwaveable heat pack held on the frozen part also works. It’s slower.
  4. Once the ice has gone, reset the boiler. The manual shows how. It may take a couple of goes.

Mind the ground afterwards. The water you’ve poured can freeze into a patch of ice right where you’re standing.

Don’t take the pipe apart, and don’t use a blowtorch or a heat gun on it.

If it keeps happening

A pipe that freezes once will freeze again in the next cold snap. It can usually be made far less likely to: lagging the outside run, fitting a wider pipe, giving it a steeper fall, or taking it to a drain inside the house instead.

If that didn’t fix it

Then it’s probably not the condensate. The boiler repairs page has a few other quick checks, and a form for the make, the fault code and what it’s doing. If the pressure gauge has dropped as well, see why a boiler loses pressure.

By Mark at MRM Plumbing & Heating, Gas Safe registered, number 302200. Last updated November 2026.

Related Boiler repairs

Get a quote

Want me to take a look?

Send me the details. I aim to ring you back within a couple of hours during working hours, and it's often the same day.

  1. 1 You fill this in. Two minutes, and it goes straight to my inbox.
  2. 2 I ring you back, aiming for within a couple of hours (Mon–Fri, 8:30am–5pm).
  3. 3 We sort out a time for me to come and look, or to do the job.

Rather ring? 07864 029690

Smell gas? Don't fill this in. Leave the house and call the National Gas Emergency Service on 0800 111 999.

Evenings and weekends I can sometimes still come out, but there is a call-out charge.

Your details only go to Mark, to get back to you about this job. Privacy